Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
Advanced Cart
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Store Locator
Statistics & Tracking
Affiliate program
Channeltracking
Conversion and usertracking via Google Tag Manager
Track device being used
Article successfully added.
From €133.70 *
Prices incl. VAT plus shipping costs
Delivery time expected 7 days.
- Catalogue no.: 123562
- Article no.: WBSWD90-00110120
- EAN: 4251636700604
- Manufacturer: Wichmann Brandschutz
- Man.-art.-no.: 110120
- Sales unit: Stück
- Packaging unit: 1
Fire-resistant bulkheading of cable penetrations in ceilings and walls according to DIN 4102-9,... more
Fire-resistant bulkheading of cable penetrations in ceilings and walls according to DIN 4102-9, S90, consisting of a galvanized sheet steel housing, lined with fire protection agent that foams in the event of fire. The cable penetration seal is to be supplied and mortared in as a finished construction element.
Cable penetration seal for
lightweight partition walls from 10 cm thick, solid walls made of masonry, concrete or aerated concrete from 10 cm thick, reinforced concrete ceilings, aerated concrete ceilings or concrete ceilings from 15 cm thick.
Cable penetration seal for
lightweight partition walls from 10 cm thick, solid walls made of masonry, concrete or aerated concrete from 10 cm thick, reinforced concrete ceilings, aerated concrete ceilings or concrete ceilings from 15 cm thick.
Approval: | Z-19.15-202 |
Fire resistance class: | S90 bzw. S120 nach DIN 4102-9 |
FTZ specification: | 736 53 FS 1/07.88 |
Installation depth: | 270 mm |
Weiterführende Links:
Available downloads:
universell einsetzbar problemloser Einbau Platzersparnis von bis zu 80% möglich Damit die... more
- universell einsetzbar
- problemloser Einbau
- Platzersparnis von bis zu 80% möglich
- Damit die Kabelbox eingemörtelt werden kann, empfehlen wir einen Mindestabstand von 1 cm zwischen der Kabelbox und der Rohbauöffnung.
- modulare, industriell funktionsfähig vorgefertigte Abschottung
- effektive 100 % Belegbarkeit, keine Beschichtungen, Beplankungen, Manschetten oder Bandagen notwendig
- auch zum nachträglichen Einbau geeinget: Kabelboxen lassen sich öffnen
- zugelassen für Kabel aller Art - ohne Begrenzung des Kabeldurchmessers
- zugelassen auch für Kabelbündel bis Ø 10 cm, Kabel müssen jedoch nicht zwingend gebündelt werden
- zugelassen für alle Leerrohre nach DIN EN 61386 mit und ohne Kabelbelegung bis zu einem Durchmesser von 63 mm
- zugelassen für Hohlleiter bis 68 mm x 41 mm und Koaxialhohlleiter bis 60 mm
- zugelassen für Bündelrohrsysteme bis 50 mm Durchmesser und Bündeladerleitungen bis 24 mm Durchmesser
1 Stück Kabelbox 1 Stück Schaumstopfen 1 Stück Güteschild 1 Stück Montageanleitung more
- 1 Stück Kabelbox
- 1 Stück Schaumstopfen
- 1 Stück Güteschild
- 1 Stück Montageanleitung