Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
Advanced Cart
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Store Locator
Statistics & Tracking
Affiliate program
Channeltracking
Conversion and usertracking via Google Tag Manager
Track device being used
Article successfully added.
€2,306.80 *
Prices incl. VAT plus shipping costs
- Catalogue no.: DVE4014651504226
- Article no.: DVE4014651504226
- EAN: 4014651504226
- Manufacturer: Benning
- Man.-art.-no.: 050422
- Sales unit: Stück
- Packaging unit: 1
PV installation tester and characteristic curve measuring device PV 2 - Installation tester for... more
PV installation tester and characteristic curve measuring device PV 2
- Installation tester for reliable testing with automatic test sequence
- Secure measurement connection even when the PV system is supplying energy
- USB interface for measured value download
- Integrated real-time clock for storing the measured values with
date and time stamp
- ISO measurement result with good/bad display
- Radio connection with Benning irradiation and temperature measuring device SUN 2
- Automatic display of voltage polarity with acoustic/visual warning in case of wrong polarity
- Direct connection to all standard PV modules with MC4 or Sunclix connector
- For
installation and repetition testing of grid-connected photovoltaic-Systems according to VDE 0126-23 (DIN EN 62446)
- Testing according to DIN EN 62446 (VDE 0126-23) and DIN EN 61829 (VDE 0126-24) for verification of power data
- Measurement of current-voltage characteristic (I-V) and power characteristic (P-V)
- Display of Umpp, Impp
and fill factor (FF)
- Automatic test sequences for characteristic measurement and Riso test
- Separate Riso measurement via 4 mm test leads for PV cables, etc.
- Suitable for solar installers (initial commissioning, retesting, troubleshooting), photovoltaic experts and service, cleaning and maintenance teams
Delivery:
Includes test leads, alligator clips, MC4/Sunclix test leads, carrying case, batteries and download software on CD-Rom.
Isolation resistance:
0.05 MOhm-199 MOhm (Riso)
0.05 MOhm-300 MOhm (2-pole).
- Installation tester for reliable testing with automatic test sequence
- Secure measurement connection even when the PV system is supplying energy
- USB interface for measured value download
- Integrated real-time clock for storing the measured values with
date and time stamp
- ISO measurement result with good/bad display
- Radio connection with Benning irradiation and temperature measuring device SUN 2
- Automatic display of voltage polarity with acoustic/visual warning in case of wrong polarity
- Direct connection to all standard PV modules with MC4 or Sunclix connector
- For
installation and repetition testing of grid-connected photovoltaic-Systems according to VDE 0126-23 (DIN EN 62446)
- Testing according to DIN EN 62446 (VDE 0126-23) and DIN EN 61829 (VDE 0126-24) for verification of power data
- Measurement of current-voltage characteristic (I-V) and power characteristic (P-V)
- Display of Umpp, Impp
and fill factor (FF)
- Automatic test sequences for characteristic measurement and Riso test
- Separate Riso measurement via 4 mm test leads for PV cables, etc.
- Suitable for solar installers (initial commissioning, retesting, troubleshooting), photovoltaic experts and service, cleaning and maintenance teams
Delivery:
Includes test leads, alligator clips, MC4/Sunclix test leads, carrying case, batteries and download software on CD-Rom.
Isolation resistance:
0.05 MOhm-199 MOhm (Riso)
0.05 MOhm-300 MOhm (2-pole).
Measured value memory: | 999 |
Protective conductor resistance: | 0,05 Ohm-199 Ohm |
Short circuit current: | 0,5 A-15 A DC |
Open circuit voltage: | 5 V-1000 V DC |
Interfaces: | USB, Funk, NFC |
Weiterführende Links: