Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
Advanced Cart
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Store Locator
Statistics & Tracking
Affiliate program
Channeltracking
Conversion and usertracking via Google Tag Manager
Track device being used
Article successfully added.
Doepke Residual current circuit breaker DFS 2 025-2/0,03-A KV, 2-pole, type A

€189.82 *
Prices incl. VAT plus shipping costs
Delivery time expected 30 days.
- Catalogue no.: 142869
- Article no.: 95300-4014712107670
- EAN: 4014712107670
- Manufacturer: Doepke
- Man.-art.-no.: 09124609
- Sales unit: Stück
- Packaging unit: 1
Residual current circuit breakers (RCCB) switch off the power supply when dangerously high fault... more
Residual current circuit breakers (RCCB) switch off the power supply when dangerously high fault currents occur. In this way, they protect people, animals and equipment. DFS 2 are double-pole residual current circuit breakers for single-phase networks. The large double-level terminals can also accommodate large conductor cross-sections. The tripped
position of the multi-function switch toggle facilitates troubleshooting. Type A breakers are pulse and AC current sensitive. This function is independent of mains voltage. Residual current circuit-breakers in KV design (KV for short-time delayed) are considerably less sensitive to short-time pulsed surge and fault currents. They thus increase
system availability. The additional protection (personal protection) is retained. The short-time delayed switches can therefore be used instead of a standard switch without any problems.
position of the multi-function switch toggle facilitates troubleshooting. Type A breakers are pulse and AC current sensitive. This function is independent of mains voltage. Residual current circuit-breakers in KV design (KV for short-time delayed) are considerably less sensitive to short-time pulsed surge and fault currents. They thus increase
system availability. The additional protection (personal protection) is retained. The short-time delayed switches can therefore be used instead of a standard switch without any problems.
Execution: | kurzzeitverzögert |
Weiterführende Links:
puls- und wechselstromsensitiv, netzspannungsunabhängig hohe Immunität gegen Stoßfehlerströme... more
- puls- und wechselstromsensitiv, netzspannungsunabhängig
- hohe Immunität gegen Stoßfehlerströme und netzspannungsgetriebene Folgestromimpulse
- geringe Verlustleistung pro Pol
- VDE-zertifiziert
- netz- und hilfsspannungsunabhängige Auslösung
- sensitiv für Wechsel- und pulsierende Gleichfehlerströme (Typ A)
- geringe Baugröße für alle Bemessungsströme
- hohe Kurzschlussfestigkeit
- beidseitige Doppelstockklemmen für großen Leiterquerschnitt und Schienenanschluss
- Schaltstellungsanzeige
- Sichtfenster für Beschriftungsetiketten
- Multifunktionsschaltknebel mit drei Positionen: Ein - Aus - Ausgelöst
- Neutralleiterposition beliebig
- Schnellbefestigung auf Tragschiene, Einbaulage beliebig, Einspeiserichtung beliebig